Has anyone had issus with their Gefens such as pops on the
audio and one of the screens going black for a few seconds?
We just got installed some CAT5-5000's and this is what I've
been dealing with.
This seems to be caused by static shock. We have 2 sets of these in
adjacent rooms and in one room the console is made out of metal; When the
operator comes in and sits down (or bangs the chair into the side of the
table), it zaps something which gets back into the Gefens and *somehow*
causes the screens in MY room to freak out. (CRTs will show a tiny little
flicker but the NEC flat panels sort of 'reset', going black for a couple of
seconds and then coming back). I also hear a pop in my RTS intercom box.
We've tried at length to isolate this, double checking that EVERYTHING is
grounded, and have never been able to get rid of this problem. I have no
idea why it's getting into the Gefens or how it's even travelling into my
room! It drives me crazy when I'm trying work and my screens go black 10
times a day.
| Bob Maple | bobm_at_burner_dot_com | [http] burner.com
|
| Thom Yorke: "Here's to getting hitched, Space Ghost."
| SG: "Yeah.. Lets drink until our hearts stop."
---
Subscribe? E-mail Majordomo(at)Softimage.COM with the following text in body: subscribe ds
Unsubscribe? E-Mail Majordomo(at)Softimage.COM with the following text in body: unsubscribe ds